Bulletin F-48

VFC Series Visi-Float® Flowmeter

Specifications - Installation and Operating Instructions 1-3/4 [44.45]

1-1/32 [26.19]

2 NOM [50.80]

1-1/2 HEX [38.10]

1-1/2 [38.10]

1-1/8 11 [28.58] [279.40] WITH BACK CONNECTIONS 1-1/8 10-1/2 [28.58] [266.70]

4-1/2 [114.30]

8-1/2 [215.90]

1-1/2 [38.10] 3 [76.20] 1-1/2 [38.10]

Back Connections The Series VFC Visi-Float® flowmeters are available in two basic styles, either back or end connected with direct reading scales for air or water. Installation, operation, and maintenance are simple and require only a few common sense precautions to assure long, accurate, trouble-free service. CALIBRATION All flowmeters are calibrated at the factory and normally will remain within their accuracy tolerance for the life of the device. If at any time you wish to re-check its calibration, do so only with instruments or equipment of certified accuracy. Do not attempt to check the Visi-Float® flowmeter with a similar flowmeter as even minor variations in piping and back pressure can cause significant differences between the indicated and actual readings. If in doubt, your flowmeter may be returned to the factory and checked for conformance at no charge. LOCATION Select a location where the flowmeter can be easily read and where the temperature will not exceed 120°F (49°C). The mounting surface and piping to the flowmeter should be free from vibration which could cause fatigue of fittings or mounting inserts. Piping must be carefully arranged and installed to avoid placing stress on fittings and/or flowmeter body. Avoid locations or applications with strong chlorine atmospheres or solvents such as benzene, acetone, carbon tetrachloride,etc. Damage due to contact with incompatible gases or liquids is not covered by warranty. Compatibility should be carefully determined before placing in service.

DWYER INSTRUMENTS, INC. P.O. BOX 373 • MICHIGAN CITY, IN 46361 U.S.A.

SPECIFICATIONS Service: Compatible gases & liquids. Wetted Materials: Body: Acrylic plastic. O-Ring: Buna-N (Flouroelastomer available). Metal Parts: Stainless steel. Float: Stainless steel. Temperature & Pressure Limits: 100 psig (6.9 bar) @ 120°F (48°C). Accuracy: 2% of full scale. Process Connection: VFC: 1˝ female NPT back connections. End connections optional. VFCII: 1˝ male NPT back connections. End Connections optional. Scale Length: 5˝ typical length. Mounting Orientation: Mount in vertical position. Weight: 24-25 oz (.68-.71 kg). PIPING Inlet Piping: It is good practice to approach the flowmeter inlet with as few elbows, restrictions and size changes as possible. Inlet piping should be as close to the flowmeter connection size as practical to avoid turbulence which can occur with drastic size changes. The length of inlet piping has little effect on normal pressure fed flowmeters. For vacuum service, the inlet piping should be as short and open as possible to allow operation at or near atmospheric pressure and maintain the accuracy of the device. Note that for vacuum service, any flow control valve used must be installed on the discharge side of the flowmeter.

Phone: 219/879-8000 Fax: 219/872-9057

www.dwyer-inst.com e-mail: [email protected]

F-48 1002:F-48 1002

7/24/09

9:19 AM

Page 2

Bulletin F-48 Discharge Piping Piping on the discharge side should be at least as large as the flowmeter connection. For pressure fed flowmeters on air or gas service, the piping should be as short and open as possible. This allows operation at or near atmospheric pressure and assures the accuracy of the device. This is less important on water or liquid flowmeters since the flowing medium is generally incompressible and back pressure will not affect the calibration of the instrument. POSITION AND MOUNTING All Visi-Float® flowmeters must be installed in a vertical position with the inlet connection at the bottom and outlet at the top. Surface Mounting Drill three holes in panel using dimensions shown in drawing. Holes should be large enough to accommodate #10 - 32 machine screws. If back connected model, drill two additional holes for clearance of fittings. Install mounting screws of appropriate length from rear. Mounting screws must not be longer than the panel thickness plus 3/8˝ (9.66 mm), or the screw will hit the plastic and may damage the meter. The screws will require additional force during the initial installation, since the insert boots are of a collapsed thread type and must be expanded into the plastic for the knurled surface to take hold. Insert boots will not have the proper 10-32 threads until the first screw has been inserted to expand the boot. Use pipe thread sealant tape or pipe thread sealant to insure against leakage. CAUTION: Do not overtighten fittings or piping into fittings. Maximum recommended torque is 10 ft. (lbs) (13.56 newton (meter)). Hand tighten only. In Line Mounting Both end connected and back connected models may be installed in-line supported only by the piping. Be sure that flowmeter is in a vertical position and that piping does not create excess stress or loading on the flowmeter fittings. OPERATION Once all connections are complete, introduce flow as slowly as possible to avoid possible damage. With liquids, make sure all air has been purged before taking readings. Once the float has stabilized, read flow rate by sighting across the largest diameter of the float to the scale graduations on the face of the device. The standard technique for reading a Variable Area Flowmeter is to locate the highest point of greatest diameter on the float, and then align that with the theoretical center of the scale graduation. In the event that the float is not aligned with a grad, an extrapolation of the float location must be made by the operator as to its location between the two closest grads. The following are some sample floats shown with reference to the proper location to read the float.

nonstandard operating conditions is as follows: Q2 = Q1 x

P1 x T2 P2 x T1

Where: Q1 = Actual or Observed Flowmeter Reading Q2 = Standard Flow Corrected for Pressure and Temperature P1 = Actual Pressure (14.7 psia + Gage Pressure) P2 = Standard Pressure (14.7 psia, which is 0 psig) T1 = Actual Temperature (460 R + Temp °F) T2 = Standard Temperature (530 R, which is 70°F) Example: A flowmeter with a scale of 10-100 SCFH Air. The float is sitting at the 60 grad on the flowmeter scale. Actual Pressure is measured at the exit of the meter as 5 psig. Actual Temperature is measured at the exit of the meter as 85°F. Q2 = 60.0 x

(14.7 + 5) x 530 14.7 x (460 + 85)

Q2 = 68.5 SCFH Air MAINTENANCE The only maintenance normally required is occasional cleaning to assure proper operation and good float visibility. Disassembly The flowmeter can be completely disassembled by removing the connection fittings and top plug. When lifting out the float guide assembly, be careful not to lose the short pieces of plastic tubing on each end of the guide rod which serve as float stops. Cleaning The flowmeter body and all other parts can be cleaned by washing in a mild soap and water solution. A soft bristle bottle brush will simplify cleaning of the flow tube. Avoid benzene, acetone, carbon tetrachloride, gasoline, alkaline detergents, caustic soda, liquid soaps, (which may contain chlorinated solvents), etc., and avoid prolonged immersion. Re-assembly Install the lower fitting and then the float and float guide. Finally install the upper fitting and plug being certain that both ends of the float guide are properly engaged and the float is correctly oriented. A light coating of silicone stop cock grease or petroleum jelly on the “O” rings will help maintain a good seal as well as ease assembly. ADDITIONAL INFORMATION For additional flowmeter application information, conversion curves, correction factors and other data covering the entire line of flowmeters, please request a Dwyer Instruments, Inc. full-line catalog.

Variable Area Flowmeters used for gases are typically labeled with the prefix “S” or “N”, which represents “Standard” for English units or “Normal” for metric units. Use of this prefix designates that the flowmeter is calibrated to operate at a specific set of conditions, and deviation from those standard conditions will require correction for the calibration to be valid. In practice, the reading taken from the flowmeter scale must be corrected back to standard conditions to be used with the scale units. The correct location to measure the actual pressure and temperature is at the exit of the flowmeter, except under vacuum applications where they should be measured at the flowmeter inlet. The equation to correct for ©Copyright 2009 Dwyer Instruments, Inc.

DWYER INSTRUMENTS, INC. P.O. BOX 373 • MICHIGAN CITY, IN 46361 U.S.A.

Printed in U.S.A. 7/09

Phone: 219/879-8000 Fax: 219/872-9057

FR# 51-440448-00 Rev. 4

www.dwyer-inst.com e-mail: [email protected]

Loading...

Specifications - Installation and Operating - Dwyer Instruments

F-48 1002:F-48 1002 7/24/09 9:19 AM Page 1 Bulletin F-48 VFC Series Visi-Float® Flowmeter Specifications - Installation and Operating Instructio...

51KB Sizes 1 Downloads 10 Views

Recommend Documents

CT-DPB - Dwyer Instruments
Dwyer started in this industry with our very popular differential pressure gages and switch ... Dwyer Instruments, Incor

Installation and operating instructions - Grundfos
2. Masukkan steker listrik ke dalam soket atau hidupkan pasokan listrik, maka pompa akan hidup. 3. Setelah air mengalir

Installation and Operating Manual - Voith
Tightening torque in Nm (dimension of thread). Coupling size ...... Please observe that the cleaning agent is compatible

INSTALLATION AND OPERATING INSTRUCTIONS INTRODUCTION
This SKYTECH remote control system was developed to provide a safe, reliable, and user-friendly remote control system fo

INSTALLATION & OPERATING INSTRUCTIONS
Sep 10, 2010 - Lighting Instructions. 44. To Turn Off Gas to Appliance. 45. XFyre Error Codes. 45. Heater Errors. 45. He

Installation & Operating Instructions - Intermatic
Re-install timer in enclosure. 8. Replace interior protective cover. PCB Latch. Interior. Protective. Cover. Timer Mecha

Standard Operating Procedure for Instruments
STANDARD OPERATING PROCEDURE: INSTRUMENTS. 3. INTRODUCTION. The Standard Operating Procedures (SOPs) for instruments, in

Installation and Operating Manual - ProSoft Technology
Thank you for selecting the Raypak B6000 Boiler Management System and the Raypak. Communication Interface. It is our ...

Installation and Operating Instructions Ethernet - Mettler Toledo
Set the IP-Address of the balance in format. “XXX.XXX.XXX.XXX”. The IP-Address must be unique within a company netwo

Bosch Axxis WFL2090UC Operating And Installation Instructions
Washer Bosch WFL 2090 Operating, Care And Installation Instructions Manual. ... Table of Contents Operating Instructions